Fix-o-Rail 55
- Total insulation
- Protection degree IP55-IK07
- Can be coupled
- Transparent door
- Adjustable DIN-rails, according the height of the DIN equipment
- For equipment up to 92.5 mm
- Padlocking option
- The transparent door can be opened to the left and the right
- Bases in Polystyreen for the 12 up to 36 modules
- ABS for the 3 up to 8 modules
- Flame resistance : self extinguishing material, resist the 650°C
- Polycarbonate for the transparent door
- Halogene free
- Flame resistance : self extinguishing material, resist the 960°C
Modular 200 Type B
- In accordance with BS5486 and BS EN 60439-3
- Durable powder coated finish
- Matching light grey throughout the range
- All incomers benefit from positive contact indication
- Modular extension boxes to install modular control devices
- Pan assembly can be easily removed to ease installation
- One piece (no welds or rivets) phase busbar – NO hot spots!
- Ample space behind pan assembly aids wiring installation
- Split terminal bars to reduce wiring installation time
- Neutral disconnect as standard to aid speedy testing
- Doors can be removed to ease installation
- Sturdy folded sheet steel construction
- Accepts 6kA, 10kA and 15kA MCB’s
- Generous wiring room even when using 1 module RCBO
- Clean earth facility available on request
- Reversible doors (left or right mounting)
- Door can be equipped with a security lock
- Document holder included
- Door on all units with bounding conductors
Modular 200 Type A
- In accordance with BS5486 and BS EN 60439-3
- Sturdy folded sheet steel construction
- Durable structured powder coated finish
- Matching light grey used throughout range
- Phase busbar rating 120A
- Incoming device cable terminal capacity 50mm²
- Terminal bar cable capacity 25mm²
- Shrouded neutral terminal bar
- Generous wiring room even using 1 module RCBO
- Comprehensive range of incomers
- Pre assembled ready to accept MCBs and RCBOs
- DIN enclosure option so you can "design it yourself"
RCCB Record Plus: FK800, 1250 and 1600 framesize
Rated at 800,1250 and 1600A, the FK frame sizes are designed for use with the FG400 and 630 frame sizes. The design uses electronic trips units available in a number of performance ranges and allowing a wide variety of setting options and groundfault protection. If needed thermal-magnetic and magnetic only trip units are also available.
The FK connection area features easy-to access busbar connections or cable lugs for use with single or multiple copper or aluminum conductors.
In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI.
- 3 and 4 pole versions available
- FK800 to 800A, FK1250 to 1250A and FK1600 to 1600A
- Full range of add-on accessories, including:
- thermal magnetic/magnetic trip units
- auxiliary contacts
- completely integrated add-on devices available
- rotary handles
- electrical operators
- connectivity – 60 mm system
- Changeover/Power transfer systems
Fix-o-Rail 150
- High protection degree: IP40
- Total insulation
- High impact strength: IK08
- 1-2-3-4 rows / 18 modules per row
- For surface mounting
- With transparent or grey door, can be opened to 180°
- For DINrail equipment up to 92.5 mm
- Optional security lock
- Generous wiring room:
- 30 mm behind the mounting frame
- 150 mm centre distance between DIN rails
- above and below the base
- shallow base
- Fixation with four captive quarter-turn screws
- Removable mounting frame
- All knockouts are easy to remove
- High impact resistance material, colour RAL 7035
- Enclosure and mounting frame are extremely sturdy
- Polystyreen for the base
- Flame resistance: self extinguishing material, resist the 650°C
- Polycarbonate for the lid
- Flame resistance: self extinguishing material, resist the 960°C
RCCB Record Plus: FG400 and FG630 framesize
Rated at 400 and 630A, the FG frame size includes all of the advanced features of the FD and FE frame sizes. The FG connection area features easy-to access busbar connections. Cable lugs for use with single or multiple copper or aluminum conductors are optionally available. The breaker is designed for use with interchangeable electronic units that can be easily adapted to multiple levels of protection.
In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI.
- 3 and 4 pole versions available
- FG400 to 400A and FG630 to 630A
- Full range of add-on accessories, including:
- thermal magnetic/magnetic trip units
- auxiliary contacts
- completely integrated add-on devices available
- rotary handles
- electrical operators
- connectivity – 60 mm system
- Changeover/Power transfer systems
Fix-o-rail Classic
- Protection degree: IP30
- IP40 with door (optional)
- Colour: RAL 9010
- 13, 26, 39 and 52 modules
- Total insulation (with backplate and door)
- Transparent or plain door
- Surface mounting
- Adjustable DINrail
- Polystyreen for the covers
- Flame resistance: self extinguishing material, resist the 650°C
- Polycarbonate for the transparent doors
- Flame resistance: self extinguishing material, resist the 960°C
RCCB Record Plus: FE160 and FE250 framesize
Rated at 160 and 250A, the FE frame sizes are designed for side-by-side mounting with FD63/160 types in panels. FE sizes are equipped with an easily accessible busbar connection and can also be supplied with cable lugs for use with copper or aluminum conductors. The design allows the use of interchangeable thermal-magnetic, magnetic-only, and electronic trip units.
In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI.
- 3 and 4 pole versions available
- FE160 to 160A and FE250 to 250A
- Full range of add-on accessories, including:
- thermal magnetic/magnetic trip units
- auxiliary contacts
- completely integrated add-on devices available
- rotary handles
- electrical operators
- connectivity – 60 mm system
- Changeover/Power transfer systems
Fix-o-Rail 150 M
- For surface mounting
- Suitable for DIN-rail mounting devices up to 70 mm as MCB’s, RCCB’s, relays, switches, timers, contactors, etc
- Manufactured from panel flat quality mild steel, cold reduced CR4 from 1.0 mm
- Pre-treated prior to powder coating, fully immersed in iron phosphate solution
- Electrostatic powder coating on a continuous line base colour RAL 7035
- Slotted fixing holes on the base permit all leveling adjustment
- Earth and neutral fitted to the base, each terminal being able to accept a 16 mm² stranded round conductor
- With DIN-rails
- Earth and neutral terminals standard
- Distance between two DIN-rails: 150 mm
- Generous wiring room
- With plain grey or transparent door
- Door opens 180°
RCCB Record Plus: FD63/160 frame size
Rated at 160A, the FD63/160 frame size is designed for use in both a DIN-rail environment with modular equipment and in industrial applications. It is supplied with IPXXB terminals suitable for direct connection of one or two conductors totalling up to 95 mm² and is available as a thermal-magnetic breaker, a moulded case switch, and as a magnetic-only motor circuit protector.
The FD63/160 bridges the gap between residential miniature circuit breakers and industrial moulded case circuit breakers.
- In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI
- 3 and 4 pole versions available
- FD63 to 63A and FD160 to 160A
- Full range of add-on accessories, including:
- thermal magnetic/magnetic trip units
- auxiliary contacts
- completely integrated add-on devices available
- rotary handles
- electrical operators
- connectivity – 60 mm system