• 11151 Amman, Jordan

VBS-Busbar system : Insulated Busbars

  • Insulated busbar, pin type system
  • Pin type for 2P or 1PN and 3P systems
  • Easy to install
  • Flat design = gain of space in the enclosure
  • Easy to use : cutting instead of sawing
  • Clear visibility when connecting the power supply cables
  • Universal for all power supplies (2 x 230V, 3 x 230V and 3 x 400 V + N)
Read More

Residential Enclosures: Flex-o-Box

Flex-o-Box Junior

 

  • Suitable for surface mounting
  • 2.5 mm² -500V
  • IP65 protection degree
  • Standards and approvals
    • CEBEC : NBN C 68-685-2-0
    • NBN C68-685-1
    • VDE: 0606 Teil1
    • KEMA: IEC 670
  • Colour: RAL 7035
  • Material: resists the 750°C incandescent wire test
  • Halogen-free
  • Operating temperature: 5°C to +60°C
  • Total insulation
  • Eight flexible entries
    • 7 x ø20 in the side wall
    • 1 x ø20 in the back
    • Suitable for cable max ø20
    • Suitable for tubes 5/8" and 3/4"

Flex-o-Box JB6

 

  • Suitable for surface mounting
  • 6 mm² – 500V
  • IP65 protection degree
  • Standards and approvals
    • CEBEC: NBN C6868520
    • NBN C686851
    • VDE : 0606
    • KEMA : IEC 670
  • Colour : RAL 7035
  • Material: resists the 750°C incandescent wire test
  • Halogen-free
  • Operating temperature: 5°C to +60°C
  • Total insulation
  • Nine flexible entries
    • 7 x PG16 in the side wall
    • 2 x ø20 mm max entries in the back of the base
    • Suitable for cable max ø20
    • Suitable for tubes 5/8" and 3/4"
    • Suitable for cable seals (8 mm min thread length)
Read More

Fix-o-Rail Senior

  • Secure : total insulation
  • Double wall : a steel outer wall plus an inner insulated extruded wall
  • Protection degree : IP41-IK08
  • Universal : for DINrail equipment up to 92.5 mm
  • Installation friendly : ample wiring room and a removable mounting frame
  • Flexible cable entries, integrated in the base

 

Read More

Fix-o-rail Europe Line

  • Protection degree: IP30
  • Masking frame, base and protective cover made from high resistance material
  • Metal door, powder coated, opens through 180 °
  • Cable entry from top, below, from side and from rear side
  • Cable entry plate (top, bottom) removable for easy cable mounting from front side
  • Clamp relief possibility
  • Sealing possible
  • Label for circuit identification
  • Rated voltage up to 400V/50Hz
  • Rated current up to 63A
  • Protection class II (total isolation)
  • Standards DIN 43871 and DIN VDE 0603 Part 1
  • For surface and flush mounting

 

Read More

Fix-o-Rail 55

  • Total insulation
  • Protection degree IP55-IK07
  • Can be coupled
  • Transparent door
  • Adjustable DIN-rails, according the height of the DIN equipment
  • For equipment up to 92.5 mm
  • Padlocking option
  • The transparent door can be opened to the left and the right
  • Bases in Polystyreen for the 12 up to 36 modules
  • ABS for the 3 up to 8 modules
  • Flame resistance : self extinguishing material, resist the 650°C
  • Polycarbonate for the transparent door
  • Halogene free
  • Flame resistance : self extinguishing material, resist the 960°C
Read More

Modular 200 Type B

  • In accordance with BS5486 and BS EN 60439-3
  • Durable powder coated finish
  • Matching light grey throughout the range
  • All incomers benefit from positive contact indication
  • Modular extension boxes to install modular control devices
  • Pan assembly can be easily removed to ease installation
  • One piece (no welds or rivets) phase busbar – NO hot spots!
  • Ample space behind pan assembly aids wiring installation
  • Split terminal bars to reduce wiring installation time
  • Neutral disconnect as standard to aid speedy testing
  • Doors can be removed to ease installation
  • Sturdy folded sheet steel construction
  • Accepts 6kA, 10kA and 15kA MCB’s
  • Generous wiring room even when using 1 module RCBO
  • Clean earth facility available on request
  • Reversible doors (left or right mounting)
  • Door can be equipped with a security lock
  • Document holder included
  • Door on all units with bounding conductors
Read More

Modular 200 Type A

  • In accordance with BS5486 and BS EN 60439-3
  • Sturdy folded sheet steel construction
  • Durable structured powder coated finish
  • Matching light grey used throughout range
  • Phase busbar rating 120A
  • Incoming device cable terminal capacity 50mm²
  • Terminal bar cable capacity 25mm²
  • Shrouded neutral terminal bar
  • Generous wiring room even using 1 module RCBO
  • Comprehensive range of incomers
  • Pre assembled ready to accept MCBs and RCBOs
  • DIN enclosure option so you can "design it yourself"

 

Read More

RCCB Record Plus: FK800, 1250 and 1600 framesize

Rated at 800,1250 and 1600A, the FK frame sizes are designed for use with the FG400 and 630 frame sizes. The design uses electronic trips units available in a number of performance ranges and allowing a wide variety of setting options and groundfault protection. If needed thermal-magnetic and magnetic only trip units are also available.

The FK connection area features easy-to access busbar connections or cable lugs for use with single or multiple copper or aluminum conductors.

In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI.

  • 3 and 4 pole versions available
  • FK800 to 800A, FK1250 to 1250A and FK1600 to 1600A
  • Full range of add-on accessories, including:
    • thermal magnetic/magnetic trip units
    • auxiliary contacts
    • completely integrated add-on devices available
    • rotary handles
    • electrical operators
    • connectivity – 60 mm system
    • Changeover/Power transfer systems

 

Read More

Fix-o-Rail 150

  • High protection degree: IP40
  • Total insulation
  • High impact strength: IK08
  • 1-2-3-4 rows / 18 modules per row
  • For surface mounting
  • With transparent or grey door, can be opened to 180°
  • For DINrail equipment up to 92.5 mm
  • Optional security lock
  • Generous wiring room:
    • 30 mm behind the mounting frame
    • 150 mm centre distance between DIN rails
    • above and below the base
    • shallow base
  • Fixation with four captive quarter-turn screws
  • Removable mounting frame
  • All knockouts are easy to remove
  • High impact resistance material, colour RAL 7035
  • Enclosure and mounting frame are extremely sturdy
  • Polystyreen for the base
  • Flame resistance: self extinguishing material, resist the 650°C
  • Polycarbonate for the lid
  • Flame resistance: self extinguishing material, resist the 960°C

 

Read More

RCCB Record Plus: FG400 and FG630 framesize

Rated at 400 and 630A, the FG frame size includes all of the advanced features of the FD and FE frame sizes. The FG connection area features easy-to access busbar connections. Cable lugs for use with single or multiple copper or aluminum conductors are optionally available. The breaker is designed for use with interchangeable electronic units that can be easily adapted to multiple levels of protection.

In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI.

 

  • 3 and 4 pole versions available
  • FG400 to 400A and FG630 to 630A
  • Full range of add-on accessories, including:
    • thermal magnetic/magnetic trip units
    • auxiliary contacts
    • completely integrated add-on devices available
    • rotary handles
    • electrical operators
    • connectivity – 60 mm system
    • Changeover/Power transfer systems
Read More