VBS-Busbar system : Insulated Busbars
- Insulated busbar, pin type system
- Pin type for 2P or 1PN and 3P systems
- Easy to install
- Flat design = gain of space in the enclosure
- Easy to use : cutting instead of sawing
- Clear visibility when connecting the power supply cables
- Universal for all power supplies (2 x 230V, 3 x 230V and 3 x 400 V + N)
VBS-Busbar System : Non Insulated Busbars
- Non Insulated busbar, pin type system or for type system, for 56 MOD
- Pin type systems 10 sqmm
- Fork type systems 10, 12, 24 and 36 sqmm
- Connector clamps
- Rails (15x3x1000mm) for L1-L2-L3-N systems
- Raised busbar terminals
VBS-Busbar system : Insulated Busbars wiht Circuit Indicator
- Insulated busbar, pin type system or fork type system with circuit indicator
- Pin type systems 10 sqmm and 16 sqmm
- Fork type systems 10 sqmm and 16 sqmm
- Both pin and fork type for 1P, 2P or 1PN, 3P, 4P and 3P+N systems
- Accessories (terminals, end caps, insulating strips)
Residential Controls Devices – Add-On RCD’s
People protection against the risk of electrocution and property protection against the risk of an electrical fire.
- In accordance with IEC 61009
- Unique connection system provides optimum user safety
- For use with 2P, 3P & 4P MCB’s up to 63A (up to 125A using HTi MCB and HTi add-on RCD)
- People protection against the risk of electrocution 10mA, 30mA and 100mA and above mainly protection against the risk of an electrical fire
- 30mA, 100mA, 300mA, 500mA and 1000mA sensitivities
- Available in type AC, A and S (Selective/Time delayed)
Tele REC: The Ultimate Reconnection System forRCCB’s
Ensures power continuity in critical applications.
The Tele REC relay automatically recloses the RCCB after an earth leakage or a manual disconnect. The relay will attempt to re-close 6 times with different time intervals between re-close attempts. After 6 unsuccessful attempts the Tele REC is locked.
Features
- Status indicator: The yellow lever clearly indicates the status of the Tele REC. In position 1 the relay is ready to work, in position 0 the relay is blocked both electrically and mechanically.
- Easy connection: The RCCB toggle slides easily into the toggle actuator of the relay.
- Part of the family: For each series of RCCB’s – ElfaPlus, Redline and DMS line – a specific Tele REC reconnector is available.
- Auxiliary contact: Tele REC is equipped with an auxiliary contact (LI) to operate the re-closing system from a push-button.
- Stable and secure: Strong clips to ensure a stable connection between the RCCB and the Tele REC relay.
- Full awareness: The relay is also equipped with a volt free output to indicate the status of the protection (connected/ disconnected).
- One fits all: Both 2 modules and 4 modules RCCB’s can be connected to the reconnection relay Tele REC.
Complete range of reconnection relays
- Tele REC DMS: Specially designed for the residential market.
- Tele REC BASIC Type A and AC: For the residential/commercial markets. Commercial, banks, office buildings, hospitals,..
- Tele REC BASIC Type Ai: Power maintenance and reliability in one device. Banks, hospitals, farms, public lighting, traffic lighting,…
- Tele REC PLUS: For the commercial/industrial markets. The reconnection relay Tele REC Plus can be easily coupled to any ElfPlus RCCB.
- Tele REC SOLAR: Specially designed for photovoltaic applications. The reconnection relay Tele REC SOLAR can be easily coupled to MCB’s series EP100 UC.
Residential Controls Devices -RCBO’s DME
Supplementary protection for people from the risk of electrocution and for property from the risk of an electrical fire. Overcurrent protection of equipment and cables.
-
Series DME
- In accordance with IEC 61009
- 6 and 10kA fault rating
- Type AC or type A
- Combines over current (MCB) and earth leakage (RCD) protection in one unit
- People protection against the risk of electrocution 10mA, 30mA and 100mA and above mainly protection against the risk of an electrical fire
- Ratings 6A, 10A, 16A, 20A, 25A, 32A, 40A
- Type B and C tripping characteristic
- Flying neutral lead version for installing in consumer units, and distribution boards
- Wire in/out (not shown) for OEM / separate enclosure installation
- 2 Module RCBO 1P+N isolates both live and neutral
- 1 Module RCBO offers space saving features and makes upgrading circuits easy
- 1 Module RCBO includes earth reference cable to provide protection in case of loss of neutral
Residual Current Circuit Breakers – RCBO’s DPA100 UL approval
People protection against the risk of electrocution and property protection against the risk of an electrical fire. Also with overcurrent protection.
- In accordance with EN/IEC 61009-1
- Recognized UL 1053, UL file E248309
- Maximum voltage AC (V) 240 or 277
- Fault current withstand (kA) 5 (277V), 10 (240V)
- Thermal settings In (A) 10-32
- Residual current IΔ n (mA) 10, 30, 100, 300
- Tripping characteristic B-C
- Selectivity class 3
- Rated maximum voltage AC Un (V) 240
- Minimum operating voltage U bmin (V) 100
- Nuisance tripping resistance 250A 8/20μs;
200A 0,5μs-100kHz - Making and breaking capacity (EN/IEC 61009-1) Im = 6000A
- Residual making and breaking capacity (EN/IEC 61009-1) Icn = 5000/10000A at 230V
- Short-circuit capacity (EN/IEC 60947-2) Icu = 15000A at 230V
- CEBEC and UR approval
Residual Current Circuit Breakers – RCCB’sseries FPAUL UL approval
People protection against the risk of electrocution and property protection against the risk of an electrical fire.
- In accordance with EN/IEC 61008-1
- Recognized UL 1053, UL file E248309
- Maximum voltage AC (V) 240
- Fault current withstand (kA) 10
- Thermal settings In (A) 16, 25, 40, 63
- Residual current IΔ n (mA) 10, 30, 100, 300, 500
- Rated maximum voltage AC Un (V) 2P: 240,4P: 240/415
- Minimum operating voltage U bmin (V) 2P: 117, 4P: 190
- Type A with 2 poles and 4 poles
- Terminal capacity flexible/rigid cable (mm 2) 35-50
- Nuisance tripping resistance Type A: 250A 8/20μs; 3000A 8/20μs
- Making and breaking capacity Im = 500A
- Residual making and breaking capacity
IΔm ≥ 500A from 16 up to 40A IΔm = 10In from 63 up to 100A - Short-circuit capacity Inc =
10000A at 230/400V fuse 80A gG - UR approval
Residual Current Circuit Breakers – RCBO’sDM100
People protection against the risk of electrocution and property protection against the risk of an electrical fire.
- Series DM100
- In accordance with IEC 61009
- 10kA fault rating
- Supplementary protection for people (up to 10/30mA) and property (above 30mA)
- Type AC or type A
- Ratings 6A, 10A, 16A, 20A, 25A, 32A, 40A
- 10mA,30mA,100mA and 300mA sensitivity options
- Type B and C tripping characteristics
- 2Module, 1P+N isolates both live and neutral
- Advanced design requires no earth lead
Residual Current Circuit Breakers – RCBO’sDM60
People protection against the risk of electrocution and property protection against the risk of an electrical fire.
- Series DM60
- In accordance with IEC 61009
- 6kA fault rating
- Supplementary protection for people (up to 10/30mA) and property (above 30mA)
- Type AC or type A
- Ratings 6A, 10A, 16A, 20A, 25A, 32A, 40A
- 10mA,30mA,100mA and 300mA sensitivity options
- Type B and C tripping characteristics
- 2Module, 1P+N isolates both live and neutral
- Advanced design requires no earth lead