• 11151 Amman, Jordan

Modular Control Devices – Contax – Relays

Used for the switching of lighting and heating loads

  • In accordance with BSEN60669-1
  • 16A nominal current
  • 1P, 2P (1 module) and 4P (2 module) with various contact combinations
  • 12V, 24V, 48V, 230V AC or DC Coils
  • DIN rail mounting
  • Circuit indicator window allowing clear labeling of circuits
  • 1 n/o 1 n/c left mounting auxiliary contact available
  • IP20 terminals
  • Contact flag indication
Read More

Residual Current Circuit Breakers – RCCB’sseries FPAUL UL approval

People protection against the risk of electrocution and property protection against the risk of an electrical fire.

 

  • In accordance with EN/IEC 61008-1
  • Recognized UL 1053, UL file E248309
  • Maximum voltage AC (V) 240
  • Fault current withstand (kA) 10
  • Thermal settings In (A) 16, 25, 40, 63
  • Residual current IΔ n (mA) 10, 30, 100, 300, 500
  • Rated maximum voltage AC Un (V) 2P: 240,4P: 240/415
  • Minimum operating voltage U bmin (V) 2P: 117, 4P: 190
  • Type A with 2 poles and 4 poles
  • Terminal capacity flexible/rigid cable (mm 2) 35-50
  • Nuisance tripping resistance Type A: 250A 8/20μs;                                                             3000A 8/20μs
  • Making and breaking capacity Im = 500A
  • Residual making and breaking capacity
                                            IΔm ≥ 500A from 16 up to 40A                                         IΔm  = 10In from 63 up to 100A
  • Short-circuit capacity Inc =
    10000A at 230/400V fuse 80A gG
  • UR approval
Read More

Residual Current Circuit Breakers – RCBO’sDM100

People protection against the risk of electrocution and property protection against the risk of an electrical fire.

  • Series DM100
  • In accordance with IEC 61009
  • 10kA fault rating
  • Supplementary protection for people (up to 10/30mA) and property (above 30mA)
  • Type AC or type A
  • Ratings 6A, 10A, 16A, 20A, 25A, 32A, 40A
  • 10mA,30mA,100mA and 300mA sensitivity options
  • Type B and C tripping characteristics
  • 2Module, 1P+N isolates both live and neutral
  • Advanced design requires no earth lead
Read More

Residual Current Circuit Breakers – RCBO’sDM60

People protection against the risk of electrocution and property protection against the risk of an electrical fire.

  • Series DM60
  • In accordance with IEC 61009
  • 6kA fault rating
  • Supplementary protection for people (up to 10/30mA) and property (above 30mA)
  • Type AC or type A
  • Ratings 6A, 10A, 16A, 20A, 25A, 32A, 40A
  • 10mA,30mA,100mA and 300mA sensitivity options
  • Type B and C tripping characteristics
  • 2Module, 1P+N isolates both live and neutral
  • Advanced design requires no earth lead
Read More

Residual Current Circuit Breakers – RCBB’sSeries BP/BD

People protection against the risk of electrocution and property protection against the risk of an electrical fire.

  • In accordance with IEC 61008
  • Additional protection for people (up to 10/30mA) and property (above 30mA)
  • Ratings 16A,25A,40A,63A,80A and 100A
  • 30mA,100mA,300mA, 500mA and 1000mA sensitivity options
  • 2P 2Module, 4P 4Module
  • High resistance to nuisance tripping
  • Type AC, A, S or types Ai and Si
  • Can be fitted with auxiliary contacts
Read More

Fix-o-rail Metal Standard

  • For surface mounting
  • Suitable for DIN-rail mounting devices up to 70 mm as MCB’s, RCCB’s, relays, switches, timers, contactors, etc
  • Manufactured from panel flat quality mild steel, cold reduced CR4 from 1.0 mm
  • Pre-treated prior to powder coating, fully immersed in iron phosphate solution
  • Electrostatic powder coating on a continuous line base colour RAL 7035
  • Slotted fixing holes on the base permit all leveling adjustment
  • Earth and neutral fitted to the base, each terminal being able to accept a 16 mm² stranded round conductor
  • With DIN-rails
  • Earth and neutral terminals standard
  • Distance between two DIN-rails: 150 mm
  • Generous wiring room
  • With plain grey or transparent door
  • Door opens 180°
Read More

Modular Control Devices – Surgeguard – Surgearresters

Used to protect home electrical appliances (TV, HiFi, VCR, washing machines, dish washers and PC’s) and commercial/industrial building equipment (computer, communications network, security, fire alarm and PLC equipment etc.) from voltage surges generated by lightning strikes, motors, frequency converters etc.

 

  • In accordance with IEC61643-1 NFC61-740
  • Protection of 1P, 1P+N (230V) and 3P+N (440V)
  • Number of modules 1, 2 and 5
  • Time saving plug in versions available
  • End of life indicators on all surge arresters
  • Some combinations with 1c/o contact
  • Imax from 20 to 80kA
  • IN from 5kA to 20kA
  • Up from 960V to 1950V
  • All MOV devices offer a built in thermal fuse
  • DIN rail mounting
Read More

Fix-o-Rail Metal Design

  • For surface mounting
  • Suitable for DIN-rail mounting devices up to 70 mm as MCB’s, RCCB’s, relays, switches, timers, contactors, etc
  • Manufactured from panel flat quality mild steel, cold reduced CR4 from 1.0 mm
  • Pre-treated prior to powder coating, fully immersed in iron phosphate solution
  • Electrostatic powder coating on a continuous line base colour RAL 7035
  • Slotted fixing holes on the base permit all leveling adjustment
  • Earth and neutral fitted to the base, each terminal being able to accept a 16 mm² stranded round conductor
  • With DIN-rails
  • Earth and neutral terminals standard
  • Distance between two DIN-rails: 150 mm
  • Generous wiring room
  • With plain grey or transparent door
  • Door opens 180°
Read More

Modular Control Devices – Series PR – PriorityRelays

Priority relays offer the possibility to limit the energy consumption in installations with a defined maximum power. This limitation is getting measuring the installation total current continuously and in the case consumption would be higher then fixed value, priority relay would disconnect the non-priority load.

 

  • In accordance with IEC 61095
  • Nominal voltage : 230V
  • Contact type : NO or NC
  • 2 Modules
  • IP20 terminals
Read More