Modular Control Devices – Contax – Relays
Used for the switching of lighting and heating loads
- In accordance with BSEN60669-1
- 16A nominal current
- 1P, 2P (1 module) and 4P (2 module) with various contact combinations
- 12V, 24V, 48V, 230V AC or DC Coils
- DIN rail mounting
- Circuit indicator window allowing clear labeling of circuits
- 1 n/o 1 n/c left mounting auxiliary contact available
- IP20 terminals
- Contact flag indication

Residual Current Circuit Breakers – RCCB’sseries FPAUL UL approval
People protection against the risk of electrocution and property protection against the risk of an electrical fire.
- In accordance with EN/IEC 61008-1
- Recognized UL 1053, UL file E248309
- Maximum voltage AC (V) 240
- Fault current withstand (kA) 10
- Thermal settings In (A) 16, 25, 40, 63
- Residual current IΔ n (mA) 10, 30, 100, 300, 500
- Rated maximum voltage AC Un (V) 2P: 240,4P: 240/415
- Minimum operating voltage U bmin (V) 2P: 117, 4P: 190
- Type A with 2 poles and 4 poles
- Terminal capacity flexible/rigid cable (mm 2) 35-50
- Nuisance tripping resistance Type A: 250A 8/20μs; 3000A 8/20μs
- Making and breaking capacity Im = 500A
- Residual making and breaking capacity
IΔm ≥ 500A from 16 up to 40A IΔm = 10In from 63 up to 100A - Short-circuit capacity Inc =
10000A at 230/400V fuse 80A gG - UR approval

Residual Current Circuit Breakers – RCBO’sDM100
People protection against the risk of electrocution and property protection against the risk of an electrical fire.
- Series DM100
- In accordance with IEC 61009
- 10kA fault rating
- Supplementary protection for people (up to 10/30mA) and property (above 30mA)
- Type AC or type A
- Ratings 6A, 10A, 16A, 20A, 25A, 32A, 40A
- 10mA,30mA,100mA and 300mA sensitivity options
- Type B and C tripping characteristics
- 2Module, 1P+N isolates both live and neutral
- Advanced design requires no earth lead

Residual Current Circuit Breakers – RCBO’sDM60
People protection against the risk of electrocution and property protection against the risk of an electrical fire.
- Series DM60
- In accordance with IEC 61009
- 6kA fault rating
- Supplementary protection for people (up to 10/30mA) and property (above 30mA)
- Type AC or type A
- Ratings 6A, 10A, 16A, 20A, 25A, 32A, 40A
- 10mA,30mA,100mA and 300mA sensitivity options
- Type B and C tripping characteristics
- 2Module, 1P+N isolates both live and neutral
- Advanced design requires no earth lead

Residual Current Circuit Breakers – RCBB’sSeries BP/BD
People protection against the risk of electrocution and property protection against the risk of an electrical fire.
- In accordance with IEC 61008
- Additional protection for people (up to 10/30mA) and property (above 30mA)
- Ratings 16A,25A,40A,63A,80A and 100A
- 30mA,100mA,300mA, 500mA and 1000mA sensitivity options
- 2P 2Module, 4P 4Module
- High resistance to nuisance tripping
- Type AC, A, S or types Ai and Si
- Can be fitted with auxiliary contacts

Fix-o-rail Metal Standard
- For surface mounting
- Suitable for DIN-rail mounting devices up to 70 mm as MCB’s, RCCB’s, relays, switches, timers, contactors, etc
- Manufactured from panel flat quality mild steel, cold reduced CR4 from 1.0 mm
- Pre-treated prior to powder coating, fully immersed in iron phosphate solution
- Electrostatic powder coating on a continuous line base colour RAL 7035
- Slotted fixing holes on the base permit all leveling adjustment
- Earth and neutral fitted to the base, each terminal being able to accept a 16 mm² stranded round conductor
- With DIN-rails
- Earth and neutral terminals standard
- Distance between two DIN-rails: 150 mm
- Generous wiring room
- With plain grey or transparent door
- Door opens 180°

Modular Control Devices – Surgeguard – Surgearresters
Used to protect home electrical appliances (TV, HiFi, VCR, washing machines, dish washers and PC’s) and commercial/industrial building equipment (computer, communications network, security, fire alarm and PLC equipment etc.) from voltage surges generated by lightning strikes, motors, frequency converters etc.
- In accordance with IEC61643-1 NFC61-740
- Protection of 1P, 1P+N (230V) and 3P+N (440V)
- Number of modules 1, 2 and 5
- Time saving plug in versions available
- End of life indicators on all surge arresters
- Some combinations with 1c/o contact
- Imax from 20 to 80kA
- IN from 5kA to 20kA
- Up from 960V to 1950V
- All MOV devices offer a built in thermal fuse
- DIN rail mounting

Fix-o-Rail Metal Design
- For surface mounting
- Suitable for DIN-rail mounting devices up to 70 mm as MCB’s, RCCB’s, relays, switches, timers, contactors, etc
- Manufactured from panel flat quality mild steel, cold reduced CR4 from 1.0 mm
- Pre-treated prior to powder coating, fully immersed in iron phosphate solution
- Electrostatic powder coating on a continuous line base colour RAL 7035
- Slotted fixing holes on the base permit all leveling adjustment
- Earth and neutral fitted to the base, each terminal being able to accept a 16 mm² stranded round conductor
- With DIN-rails
- Earth and neutral terminals standard
- Distance between two DIN-rails: 150 mm
- Generous wiring room
- With plain grey or transparent door
- Door opens 180°

Modular Control Devices – Series PR – PriorityRelays
Priority relays offer the possibility to limit the energy consumption in installations with a defined maximum power. This limitation is getting measuring the installation total current continuously and in the case consumption would be higher then fixed value, priority relay would disconnect the non-priority load.
- In accordance with IEC 61095
- Nominal voltage : 230V
- Contact type : NO or NC
- 2 Modules
- IP20 terminals

Fix-o-Rail Covers
- Protection degree : IP30
- Made from high resistance ABS
- Flame resistance : self extinguishing material, resist the 960°C
- Colour : Grey RAL 7035
- Installation temperature : 15°C up to +60°C