Ratings from 2 Amps to 1250 Amps
Fully complies with the requirements of BS88 Parts 1 & 2 and the associated IEC269
ASTA 20 certified performance to 80kA, generally at 660Vac
ASTA certified at 40kA up to 460Vdc
Suitable for use in motor circuits and have superior motor starting ability, the availability of extended motor range Fuse Links (gM) enhances this capability
Used to provide certified Type 2 co-ordination to IEC947 together with the contactors and overload relays
Approved by leading authorities, including Power Generation Companies and Ministry of Defence
Read More
Time delay Fuse Links are used in conjunction with circuit breaker overcurrent releases
"XF" range is designed and manufactured in accordance with ESI 12-6 Time Fuse Links
"XF" range should be used on all new installations
Available in ratings from 3 Amps to 15 Amps
"TLF" range is an old design of time delay Fuse Link
"TLF" range should only be used for replacement purposes
Available in ratings of 5 Amp, 7.5 Amp and 10 Amp
Read More
Range of lightweight, high performance Fuse Links for use in Aircraft
Certified for categories of duty 250AC3 and 120DC3
Comply with the requirements of BS 88 and BSG 176
Current rating of "AS" range is 0.25 Amps to 20 Amps
Available with ferrule termination or alternatively tag contact type (designated "AST")
Current rating of "UA" range is 30 Amps to 300 Amps
Motor circuit version also available (designated "UAM")
Approved by the "Air Registration Board"
Read More
Special range of Fuse Links developed for the armed forces for general purpose applications
Developed in accordance with DEF STAN 59-96
Range is now classified under NATO stock numbers which are universally recognised
Available as end contact (ferrule) & tag contact type in up to 5 body sizes
Current ratings from 0.25 Amps to 200 Amp
Voltage rating up to 440V ac and 230V dc 33kA
For use in all types of ships with Lloyds certified equipment
Read More
1.2kV and 1.5kV for Industrial and General Applications
Current range from 2 Amps to 400 Amps
Range has been tested to BS 2692 at 1200 and 1500 Volt a.c 63kA
Certified dc short circuit performance of 660V 50kA to BS88 also tested to a minimum of 750 Volt dc
Read More
For use in air to protect Distribution Transformer Circuits
Current ratings from 6 Amps to 250 Amps
Voltage range from 7.2kV to 34.5kV
Meets dimensional requirements of DIN 43625 and is tested to IEC282
ASTA and/or KEMA certified short circuit testing
Suitable for both indoor and outdoor applications
Widely used at system voltages of 2.4kV to 34.5kV in distribution circuits
Read More
For use in air on motor starting and general applications
Current ranges available:
5A to 450A at 3.6kV
50A to 350A at 7.2kV
32a to 350A at 12kV
Meets dimensional and performance requirements of BS 2692 & IEC282
ASTA and/or KEMA certified short circuit testing
High current rating in single body dimensions
Low current and energy let-through under max fault conditions
Excellent performance under low over-current conditions
Ability to resist ageing under repeated starting conditions
Read More