• 11151 Amman, Jordan

RCCB Record Plus: FK800, 1250 and 1600 framesize

Rated at 800,1250 and 1600A, the FK frame sizes are designed for use with the FG400 and 630 frame sizes. The design uses electronic trips units available in a number of performance ranges and allowing a wide variety of setting options and groundfault protection. If needed thermal-magnetic and magnetic only trip units are also available.

The FK connection area features easy-to access busbar connections or cable lugs for use with single or multiple copper or aluminum conductors.

In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI.

  • 3 and 4 pole versions available
  • FK800 to 800A, FK1250 to 1250A and FK1600 to 1600A
  • Full range of add-on accessories, including:
    • thermal magnetic/magnetic trip units
    • auxiliary contacts
    • completely integrated add-on devices available
    • rotary handles
    • electrical operators
    • connectivity – 60 mm system
    • Changeover/Power transfer systems

 

Read More

RCCB Record Plus: FG400 and FG630 framesize

Rated at 400 and 630A, the FG frame size includes all of the advanced features of the FD and FE frame sizes. The FG connection area features easy-to access busbar connections. Cable lugs for use with single or multiple copper or aluminum conductors are optionally available. The breaker is designed for use with interchangeable electronic units that can be easily adapted to multiple levels of protection.

In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI.

 

  • 3 and 4 pole versions available
  • FG400 to 400A and FG630 to 630A
  • Full range of add-on accessories, including:
    • thermal magnetic/magnetic trip units
    • auxiliary contacts
    • completely integrated add-on devices available
    • rotary handles
    • electrical operators
    • connectivity – 60 mm system
    • Changeover/Power transfer systems
Read More

RCCB Record Plus: FE160 and FE250 framesize

 

Rated at 160 and 250A, the FE frame sizes are designed for side-by-side mounting with FD63/160 types in panels. FE sizes are equipped with an easily accessible busbar connection and can also be supplied with cable lugs for use with copper or aluminum conductors. The design allows the use of interchangeable thermal-magnetic, magnetic-only, and electronic trip units.

In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI.

 

  • 3 and 4 pole versions available
  • FE160 to 160A and FE250 to 250A
  • Full range of add-on accessories, including:
    • thermal magnetic/magnetic trip units
    • auxiliary contacts
    • completely integrated add-on devices available
    • rotary handles
    • electrical operators
    • connectivity – 60 mm system
    • Changeover/Power transfer systems

 

Read More

RCCB Record Plus: FD63/160 frame size

Rated at 160A, the FD63/160 frame size is designed for use in both a DIN-rail environment with modular equipment and in industrial applications. It is supplied with IPXXB terminals suitable for direct connection of one or two conductors totalling up to 95 mm² and is available as a thermal-magnetic breaker, a moulded case switch, and as a magnetic-only motor circuit protector.

The FD63/160 bridges the gap between residential miniature circuit breakers and industrial moulded case circuit breakers.

 

  • In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI
  • 3 and 4 pole versions available
  • FD63 to 63A and FD160 to 160A
  • Full range of add-on accessories, including:
    • thermal magnetic/magnetic trip units
    • auxiliary contacts
    • completely integrated add-on devices available
    • rotary handles
    • electrical operators
    • connectivity – 60 mm system
Read More

RCCB Record Plus: Thermal magnetic, magnetic andelectronic trip units

The trip units are designed to protect circuits and/or the equipment connected to these circuits and exist as electromechanical or electronic devices. Numerous electromechanical types are available as thermal magnetic devices with overload and short-circuit protection or magnetic-only types providing short-circuit protection. Electronic devices offering wide setting ranges and a more sophisticated level of protection are available in several versions. Each trip unit has a setting area finished with a sealable transparant trip unit door.

 

Electromechanical devices

Devices available in a current range of 16 to 1250A(1) as single, two, three or four pole devices. The electromechanical trip units exist as thermal magnetic, magnetic-only and generator protection models.

The high performance thermal magnetic trip units exist as selective and non-selective versions and are equipped with a fault indicator that distinguishes between overload and shortcircuit events in accordance with HD 384.

This patented safety feature allows users to reduce downtime by resetting the breaker directly after an overload event.

 

Electronic devices SMR1 and SMR2

The SMR1 and SMR2 types offer adjustable overload and selective short-circuit protection. The SMR1 range is designed for simplicity and includes numerous exciting features as an overload signalling option, a built-in temperature sensor and rating plugs suitable for both line and motor protection.

The SMR2 has been designed to provide a flexible solution for all protection scenarios.The device is available in two versions, each allowing the user to conveniently tailor his protection to meet individual circuit requirements.

The available options include adjustable overload pickup values, overload trip time characteristics, short time pickup circuit values, short time delay circuit trip times and energy values. The trip unit can be equipped with a ground fault protection and is also available with a load shedding option.

Read More