Low Voltage Industrial Fuse Links: CanadianStandard
- Range of HRC Fuse Links designed, fully tested and CSA approved as meeting the requirements of C22.2 No. 106-M1992
- HRCI Fuse Links provide both overload and over current protection
- Used in a wide variety of applications
- HRCI are fast acting and are ideally suited for use on feeder circuits and loads which are mainly resistive
- HRCII are CSA certified for an interrupting duty of 200kA at 600 Volt a.c
- Also conform to IEC 269 for use at 600 Volt a.c
- Provide good all round general purpose characteristics, making them ideally suited for both overload and motor circuit protection
Types ‘NHG’ AND ‘NHA’
- Ratings from 6 Amps to 630 Amps
- Body sizes 00C, 00, 0, 1, 2 and 3
- Complies to VDE 0636/21 class gL and IEC 269-21
- Rupturing capacity of 120kA at 500 Volt a.c
- Knife-blade tags, European dimensional standards to DIN 43620
- General Purpose, gL (gG) and Motor Starting, Am (gM) available
SAFECLIP Low Voltage Industrial Fuse Links – Offset Blade Tag
- Ratings from 2 Amps to 125 Amps
- Fully complies with the requirements of BS88 Parts 1 or 6
- ASTA 20 certified performance at 240/415/440 Vac 80kA
- Low power loss values, well within the limits specified in BS88
- Off-set blade tag type for clip-in mounting provides economies in size & installation time
- Suitable for use in motor circuits and have superior motor starting ability, the availability of extended motor range Fuse Links (gM) enhances this capability
Red Spot 400 Series Compact
- Ratings from 2 Amps to 400 Amps
- Fully complies with the requirements of BS88 Parts 1 & 2 and IEC269
- ASTA 20 certified performance of up to 415/440Vac at 80kA
- Excellent short circuit energy limitation
- The compact design offers the user the advantage of reduced size and cost saving, whilst maintaining superior electrical and thermal performance, meets the demands of over 80% of the market
- Suitable for use in motor circuits and have superior motor starting ability, the availability of extended motor range Fuse Links (gM) enhances this capability
Red Spot Standard
- Ratings from 2 Amps to 1250 Amps
- Fully complies with the requirements of BS88 Parts 1 & 2 and the associated IEC269
- ASTA 20 certified performance to 80kA, generally at 660Vac
- ASTA certified at 40kA up to 460Vdc
- Suitable for use in motor circuits and have superior motor starting ability, the availability of extended motor range Fuse Links (gM) enhances this capability
- Used to provide certified Type 2 co-ordination to IEC947 together with the contactors and overload relays
- Approved by leading authorities, including Power Generation Companies and Ministry of Defence