Contactors for Capacitors Switching – Series CSCN

With built-in resistance to switch three phase capacitor banks

“CSCN” contactors incorporate a front block with three early-make auxiliary contacts together with 6 quick discharge resistors (two per phase) through which the capacitors are switched to the network, reducing the current peak.
Once the resistors have damped the current peak, the main contacts shortcircuit the resistors, carrying the uninterrupted current.
A few miliseconds later the early-make auxiliary contact closes to guarantee that all current flows through the main contacts.

Read More

Industrial contactors (Upto 450 kW) – Series CL and CK

  • IEC 947 standards compliant
  • Complete range:
    • 3 pole 4 – 450 kW at 400V, 9 – 105A AC3 rated
    • 4 pole 25 – 1250A AC1 rated
  • DIN rail mounting up to 55kW. Panel mounting across the whole range
  • A wide range of AC, DC and Electronic coil control voltages. DC operating limits 0.8…1.1 Us and operating limits 0.7…1.3 Us
  • Terminals in accordance with EN 50005, 50011 and 50012. Degree of protection IP20
  • Wide range of accessories:
    • Timers
    • Interface devices
    • Supressors RC, varistor and diode
    • Auxiliary contact blocks side mounting, also front mounting 4 -55kW
    • Mechanical/Electrical interlocks
    • Mechanical latch 4 -55kW.
  • Spare coils and contact kits available
  • Wide voltage tolerance DC coil control
  • Energy efficient low power coils
  • Quiet operation DC and Electronic coil control
Read More

Minicontactors (Upto 5.5 kW) – Series M

 

  • IEC 947 standards compliant
  • 3-pole: 2.2kW to 5.5kW – 380/415V – AC3, 6 to 12 A – AC3
  • Control circuit :AC, DC, low coil consumption (1.2 and 2W/24V). DC operating limits 0.8…1.1 Us and operating limits 0.7…1.3 Us
  • 4-pole: 20A AC1,Control circuit : AC, DC
  • Available in 3 different contact configurations
  • Terminal protection degree IP2X
  • Terminations: Screw, Ring Terminal, Fast-on – 2 x 2.8 mm (on request 1 x 6.3 mm) and Printed Circuit Board configurations
  • Terminals:
    • Numbered according to EN standards
    • Posidrive terminal screws
    • Mounting in line.
    • Terminal numbering in accordance with EN50012 and EN50005.
  • Coils:
    • Protected against overheating
    • Easily interchangeable
    • Spare parts
    • Wide Tolerance 0.7 – 1.3 x Us
  • Mounting:
    • 35 mm DIN-rail mounting or screw fixing
  • Accessories:
    • Front mounting auxiliary contact blocks.
    • Two and Four pole contact configurations.
    • Protection degree IP20.
    • Side mounting auxiliary contact blocks.
    • Single circuit contact blocks.
    • Common for AC or DC contactors.
    • Possible to mount up to 4 blocks in tandem.
    • Delay ON Electronic timer for front, side or DIN mounting timing range 0.5 – 60 sec and 0.2 – 24 sec.
Read More